British General 900 Series 45A 1-Gang DP Cooker Switch White with Neon (67918) (26) £7. #2. Divide the rating in watts by 230 (volts) to get the current draw figure. Raised Square Profile. Screwed Faceplate. Frustrated female New Member. One wire in the Left hand terminal looks a bit dodgy. The pan base heats up. Simple to clean. New ceramic electric hob to replace existing gas. Timer. 0800 324 7818. (Gas CH/HW still needs electricity. 500062. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. is 680502. Product information. I will follow your advice to get a 13amp max oven and just have the oven and GAS Hob connected. Free returns. Water & Flame-Resistant. Choose options. Appliances then hardwired to outlet plate. Job I was called to today. 13 Inc Vat. Requires 25mm Back Box. Single oven yes. It's a heavy base wok so distributes heat evenly unlike a thin carbon steel wok. Front-mounted touch controls. 6 x 49. More precise cooking. I have searched the internet and not found an answer that is specific to gas hob and electric oven. 6kW) and Ceramic hob (7. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. Cooker is reactivated by resetting the system once the cause of the alert has been investigated and controlled. Screwfix customers rate this product 4. com. Bazza Screwfix Select. Delivery 7 days a week. Stock Number ES1781989. Well the hob is rated at 7. There are many different ways, 3 circuits has its benefits if you have room in cu. Just put them both underneath the Hob and stop worrying. It can move around slightly and I'm worried that with it not being secure it might affect the. Work out the total power in W of both units, for you that is 6000W + 4200W, = 10200W then divide by 230V = 44. 4mm heat resistant flex, wire neutral to N1 or N2 live to L1 or L2 leave the links in, using the 220 to 240 picture. Hob: must have a minimum thickness of 30 mm. Child Safety Lock Mechanism. Delivery. ★★★★★ Read 9 reviews. I bought it about 8 years but never got around to fitting it so I thought it would be better than the one she has got . 1-800 932 230. Hi all, I've just tried wiring an indesit IB65B60 induction hob. Choose options. 4. Click & Collect. Please do not return to store. 1. Plug In and Go. Available in styles & finishes to suit your kitchen. Gas or Electric hob. I think I might be able to explain why the hob has two cables. (6mm2 T&E feed to switched spur, 2. It is to replace exisiting. com. Supplied in a variety of fuel options, this type of equipment is easy and simple to use and has different configurations available to get the best fit for a design. 5kW. I already have one on the kitchen wall which feeds my fan oven. , Mar 15, 2018. 3) 220-240V 3 ~ H05V2V2-F 4G 2. Many thanks for your reply A tiny bead of clear sili, then wiped with a water and washing up liquid dipped finger or sponge will seal this. The AEG Pure 3 hob combines a sleek, seamless design with responsive functions. Electric and gas options make classic choices, while induction is. You may find that they will clamp down on 50mm tops. Warranty: 2 year warranty. Peter160482 New Member. 7kw loads and. 1/5. £72. At the CU, there is a 30A switch labelled 'cooker' which when flicked down turns off the cooker and the 2 gang socket. The Happy Builder Screwfix Select. Hi have recently purchased a neff induction hob,set up so far is 6mm cable running from 32amp mcb to 45amp isolator to 45amp connection terminal. 99Inc Vat. But there's not the prescribed 15mm of space between the oven and worktop - it's covered with a small wood panel that's started to fall down on one side. Works out when the temperature of cooking is too high and turns off the source of ignition, effectively preventing kitchen fires before they start. So :Hot plate hobs such as ceramic, traditional metal electric hobs, and one tonne lumps of hot cast iron (aka Aga) transfer heat to the pan by contact so the pan bases need to be flat. Induction hob featuring Autoconnect technology LinkSense, allowing wireless RF connection to compatible hood. Buy any 10+ Save 10% - View Offer. electric oven hob; Page 2 of 2 < Prev 1 2. Check the overall measurement of your new hob to see if it will. Several options available. You could always think of another way though. 476-03-04 Every fixed or stationary appliance which may give rise to a hazard in normal use. 6 x 49. From £780. Boost function. My question is, what is an omnipolar cut. The induction hob will require max of 6kw/240v = 24 amp. Home Forums > Screwfix Community Forum > Electricians' Talk > New Hob. What there is though is manufacturers fitting instructions, which should include the minimum distance from combustible material. FREE next day delivery available, free collection in 1 minute. P=Power, V=Volts, and I = amps P = V x I P/V = I 8800/240 = 36. electric hob trips whenever either of the two bigger plates are switched on. The oven circuit is fused at 32A. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. W x H x D: 260 x 90 x 7mm. Click & Collect. re the oven, best if also connect this to the existing 32A circuit. Which is what you require. I have a new 13 amp oven coming which will have a three pin plug & a. sparko69 Screwfix Select. Lectrician Screwfix Select. Garry Ingham said:. Buy Bathrooms & Kitchens at Screwfix. 29 Inc Vat. Frustrated female New Member. 56 Amps total, with diversity. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. (a common problem on older oven and hob elements). "drop test " on the meter to make sure that the. I have seen one oven and hob at 10. Wife's son as give me an induction hob he as had given, to install. We have the hob on top of two single ovens. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. The new induction hob has 10, 13, 16 & 20 Amp power options with max 7. Sign in / Register. 7 KW) Induction or 2 x Ø 190 mm, 2. #2. Suitable for use on domestic stoves, furnace chimneys, industrial ovens and exhausts. seneca Screwfix Select. 10mm would be best as this is a slightly larger than normal cooker. 0800 324 7818. ie. 5kw for the hob, a total of 10kW. He said he could help me out and complete the cooker line. 1/5. This is why 3kW immersion heaters are on separate circuits. Home Forums > Screwfix Community Forum > Plumbers' Talk > Propane Gas Hob. I have a new electric hob , the earth terminal is marked but the other 2 are not so does it matter which goes to the live and. Only the sealing strip can be used. Heat-Resistant up to 600°C. FREE next day delivery available, free collection in 1 minute. 2 x Ceramic Plates. if I get a replacement hob for my cracked glass hob do I need to be careful what side the terminals are on?Hi all, planning to replace my electric ceramic hob for an induction one. Sparkielev said: ↑. There's an existing dedicated cooker supply to a 32A breaker in the CU, via a 45A cooker isolation unit (the unit also has a. 25m Length. Child Safety Lock Mechanism. At present the oven is hard wired into a connection plate at the back of the oven. Neither have any cables attached, but both state 4mm cable on the connection points. Both the old and new hob are rated at 5. 5KW and I have put it on a 32A breaker, with 6mm cable. 49 Inc Vat. Buy any 10+ Save 10% - View Offer. Wiring a 7. Single-Sided. Personally don’t. Buy Cooker Hoods at Screwfix. Discussion in 'Electricians' Talk' started by jasondo23, Dec 6, 2009. Choose from top trade brands. the gas connection to the free standing cooker is by means of a flexible rubber pipe with bayonet fitting. Low price guarantee at BestBuy. Bostik FP401 Fire Resistant Acrylic Sealant White 310ml (572JE) compare. 5mm, does this mean I use a 2. Requires 47mm Back Box. The designer of the circuit has determined that the 32 amp MCB is the suitable OPD for the circuit. 7 kW into a single ring, where the 13A socket can only. Home Forums > Screwfix Community Forum > Electricians' Talk > AG Electric Hob ? Discussion in 'Electricians' Talk' started by Sharon151, Jun 21, 2014. Ah ok so it's the same wiring as an electric hob, but slightly more complex is that right? HannahBanana, Sep 13, 2017. Electric Hob or Induction hob, or even gas? Discussion in 'Electricians' Talk' started by MrM, Nov 25, 2019. Done right it could look quite good. Bazza said: ↑. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric hob. Pay your way. The existing socket is most likely on 2. View all: No Nonsense Spray Paints. 3kw induction hob on its own radial circuit protected by a 32amp MCB. This oven was in the tower cabinet which has ventilation at the back of cabinet and now I want to move this oven to the 'under the gas hob' position. So for a new cooker circuit, will they install a double socket under the worktop to plug in the electric oven and electric hob, then a single fused switch above worktop to control both at the top like this? If the induction hob will run on 16A single phase, the results will be disappointing. Induction Hob says its depth is 44mm. The hob will need to sit into some form of worktop. View all: MK Flex Outlets. I originally thought this meant to use either 5 or 3 cables. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm (420FH) (73) compare. kitfit1 Screwfix Select. Oven and hob packages. 9% APR representative (variable)* +2 more offers. That way you are not only testing it for functionality (like it heats up) but also the RCD will trip idf there is an earth leakage fault. You should use the existing cooker circuit for the new oven, to reduce the load on the ring (socket) circuit. Most DOUBLE electric ovens are rated over 3kW and require their own 32A radial circuit and will not have any connection pre-wired. 2kW more. Repair Service Contact. 2 KW (max. Its always better to have these sorts of load on a dedicated circuit. The Happy Builder, Feb 11, 2021. 00. Several light coats will give a better finish than a single heavy coat. Should an ceramic electric hob go through an rcd? the one i have if wired through the rcd trips it out when switched on. Having ploughed through loads of specification on AO. 0800 324 7818. the thicker one is the hob. I do not have the luxury of being able to run a new cable from the CU, not without a lot of disruption to many rooms. You can get Ovens that plug in but not Hobs! Get a 6mm feed run in by a reputable Spark, it won't be THAT much! sinewave, May 25, 2007 #30800 324 7818. 30 day money back guarantee. 60 days free credit available. 30 day money back guarantee. I was going to fit a dual appliance outlet, and a 13amp switch, and wanted to confirm if the 45a switch should go before or after the dual appliance outlet (see diagram). Below is the specifications for my old hob (which is now out of stock), underneath is a link to a new one i think will be a like for like swap, it is the same size and same amp, is there anything else i have overlooked? Model name/number CLIND1BK-C Colour Black Material Ceramic Fuel Electric Hob type Induction Number of burners 4. £4. I need to replace a gas hob with an electric hob and there is already an electric oven there. Hello. If the hob is relatively new, don't use silicon as it will probably invalidate the manufacturer's guarantee. AEG IPE84531FB Induction Hob with PureHob - 80cm. And the hob we are getting is a 30a hardwired. Very few of the manufacturers/retailers actually state what the ratings are, they merely state "Hardwire required", which i assume means larger than 13A (std plug). Raised Slim & Rounded Profile. MGW Screwfix Select. It provides a protective barrier between the hob cabinet and the underside of the hob. Lee58 New Member. The hob normally around 100 mm less, giving you around 45mm of worktop in front and behind the hob. Can anyone recommend a paint I can use? or would you not recommend trying to do this?. Number of Cooking Zones: 2 Zones. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. Hob. Safety Gas Cut-Out. Total Product Weight. 43a 7000w. I am planning my kitchen and the hob I have chosen is 7. Davie Active Member. Looking at gas hobs that are 75 x 51 cm the holes required are. All that said there are practicalities that. I would prefer to have oven and hob on cooker circuit, then separate 20a circuit for microwave, which could also accommodate extractor hood too. Hi, I have some rust on the trim around my electric cooker top and I would like to try and repair it. No Timer Function. currently have a dual fuel free standing cooker (gas hob electric oven) this is being changed for a built in oven and separate gas hob. Some of the hobs are pretty pants for sitting flat on the worktop. London. 5mm" and that "for this connection a power lead of wire type H05VV-F should be used". Repair Service Contact. If the oven is designed to be plugged in via a 13A socket then it will be supplied with a factory fitted flex and moulded 3 pin plug. There is nothing wrong with this and it's within the Regs and done all the time. £4. Neither the hob or the oven should be more than 2 Mts from the control. I’m not an expert in this field but as it is would seem the back right hob ring will be very close to the gas supply pipe running down the wall. Ask a question. Screwfix Community Forum. I know I need to put an unswitched cooker outlet plate at. Raised Square Profile. It goes straight down into the ground, underneath the kitchen floor tiles, over to the other side of the kitchen where it is hardwired in. about to purchase a separate electric oven and electric hob, at the moment I have a cooker point supplied with 10mm cable from consumer unit. There is dedicated 32amp supply from CU to a cooker control switch (above counter); behind the oven housing unit there is double socket with a 10mm cable spurred from the cooker control switch. Inline Relays. Some hob manufacturers differ from these dimensions. A hob separator plate is a piece of sheet metal installed on the underside of your hob. 2) 220-240V 2 ~ H05V2V2-F 3G 2. Screwed Faceplate. Once you have cut the pipe then you will need to do a. HannahBanana New Member. Just twice in the last few days. metrokitchens Screwfix Select. Free next day delivery available. Hob Control Knob - Black/Chrome. Screwfix customers rate this product 4. The touch panel controls are not working to increase, lower or shut down the hob. Some have bigger terminals than others which makes the job easier, other wise change it to the one suggested above. Cheers mate. If it works with L1 and L2 together, with the marking of “25A” usually meaning per phase, it is going to give 50A on the neutral at full load. Product Width. most hobs need minimum of 4mm cable and a 32 amp fuse at the consumer unit supplying only the hob. The process you describe above is more like how a microwave oven works. com. I want to run the cable from the kitchen to the cupboard where the consumer unit is myself and then get the electrician to install the ovens and hob at one end and do the work on the consumer unit (we may need a new consumer unit but the electrician sill sort all that out). While I was pondering my options it occurred to me that as induction hobs don't stay warm for an extended period there's perhaps the possibility to in effect fit the induction hobs 'below' the worktop say 30-40mm and have a 'slow close' hinge (s) at the rear of the workspace with a 'fold down' worktop, that closes say 3-5mm above the. 60 days free credit available. Automatic switch-off timer and up to 9 adjustable power levels per zone. #4. So in your case we would have 3. 5kw) and electric oven (rated at 2. Several light coats will give a better finish than a single heavy coat. Order online at Screwfix. 1. Dan Parkinson, Jul 27, 2020. 85 kg. I just thought 2. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. PayPal accepted online. READ NEXT: Best gas hobs. According to Neff, for the hole cut out of the worktop, the minimum front and back distances from hob to back wall and front edge to counter are 50mm. Features 4 functions including grilling and plate warming. Delivered by our approved supplier, Find out more. Ah no. 2A (=10. PayPal accepted online. It's a new build, only 4 years old and has been fine. If it needs hardwiring, get a dual appliance connector plate. Read on to see which ones made the cut. richard Kenward New Member. Discussion in 'Just Talk' started by koolpc, Aug 27, 2022. 300008. I went round the house turning everything off and finally identified the culprit - my gas hob! I turned it off at the isolator switch above the worktop and then I. 47 x 30 % =10. 79 Inc Vat. I’d be surprised if it didn’t fit. Agreed UP, 10mm for a standard domestic cooker circuit is a total waste of money (and copper!) seneca, Feb 28, 2017. I'd be grateful for any help with the following. I currently have a cooker control unit supplied with 6mm cable & 32A mcb, & a single ccu under the. whatever you have laying about. 3. However if the hob is a few years old, the use silicon. Even heat distribution. Screwfix Community Forum. Non-Dimmable. I intend to replace the single cooker by separate hob and grill/oven units with a total power consumption intended to be no more than the existing cooker. jasondo23 New Member. Buy Air Vents at Screwfix. Check the kW rating of the hob, in most cases a 6. unphased, Feb 4, 2018. Now obviously this is not good and ive recommended a different layout of the kitchen and to try get the hob above some cupboards where theres. Delivery. £ 3. Moving from gas to electric, my current gas oven is 13 amp which the new electric oven will also be so I'm confident that will work, but I'm worried about the hob. 00. £5. Stainless steel finish. Looking at the oven although its 880 height (including legs) the top is basically the controls with beding that 40mm lower. Delivered by our approved supplier, Find out more. 0mm H05 flex for hob to outlet plate as it’s current demand is 30. I hope this the right thread. 0800 324 7818. It will most likely have a 45A switch on it. Electric screwdrivers are a key piece of kit allowing the user to screw and unscrew as required with complete ease. Our current gas oven depth is 523mm & the depth of the electric oven is 560mm. Home Forums > Screwfix Community Forum > Electricians' Talk > New electric hob. Add to wishlist. Single oven yes. 2 x Ceramic Plates. Clarky94 said: ↑. (At the moment we have a seperate gas hob) The old oven and gas hob will be replaced with: - Induction Hob - the rating is 6. 4KW load, ideally I'd like to be able to have the 20Amp option to get the most out of it. Power indicator and automatic switch-off timer to control each zone. If the drainer is on the Hob side, then I'd be OK with it at 200mm. 3000w for 13A input. Having a switch on the wall doesn’t mean you can install an electric hob and oven, it might only be rated for supplying the clock and ignition on the gas cooker. The connection units will be fine behind. Having ploughed through loads of specification on AO. Permanent Adhesive. Now we take off the first 10 amps and then use 30% of the remainder so, 33. Hi, I wondered if someone can help me with a wiring issue. 9Kw/32amp and hob is at 11. com. Other users reply with their opinions and advice, including the difference between. Repair Service Action. I think I'm going to use silicone. Order Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm at Screwfix. 98 Inc Vat. £11. If your gap is 630mm you'll need to cut two filler pieces either side of the housing. Several options available. Just bought a new gas hob (rated at 7. The thread also includes links to products and specifications of different hobs. I have bought a new kitchen. Please do not return to store. This oven is not a 'built under' style but a 'built in' type 600x600mm standard size single oven. Is is normal practise to wire both appliances into the outlet that is supplied by the 45A DP cooker switch on the wall? I appreciate your time if you can. Repair Service Action.